A service that Vubiq Networks, Inc. offers our customers is performance monitoring of our links out in the field. We monitor the links using SNMP, Simple Network Management Protocol, data. In order to capture the SNMP data we only need IP access to the terminal via a public IP address or a VPN and the Read SNMP Community string, typically “public”.
The SNMP variables and their alarm limits that give us the most information are:
- Vubiq RF DSSI, OID: 1.3.6.1.4.1.46330.2.2.1.7.0
Digital signal strength indicator from 0 (no signal) to 100 (perfect signal). Integer32 (0..100), Read Only
Vubiq recommends: Warning limit: below 90%; Error limit: below 50% - Vubiq RF Board Temp, OID: 1.3.6.1.4.1.46330.2.2.1.15.0
Board temperature in ⁰C. Integer32, Read Only
Vubiq recommends: Warning limit: above 80 ⁰C; Error limit: above 85 ⁰C - Vubiq RF TX Temp, OID: 1.3.6.1.4.1.46330.2.2.1.16.0
Transmit module temperature in ⁰C. Integer32, Read Only
Vubiq recommends: Warning limit: above 70 ⁰C; Error limit: above 80 ⁰C - Vubiq RF RX Temp, OID: 1.3.6.1.4.1.46330.2.2.1.17.0
Receiver module temperature in ⁰C. Integer32, Read Only
Vubiq recommends: Warning limit: above 70 ⁰C; Error limit: above 80 ⁰C - Vubiq RF Board Uptime, 1.3.6.1.4.1.46330.2.2.1.19.0
The number of seconds since the unit was powered on. Basically, (sysUpTime * 100). Integer32, Read Only
Vubiq recommends: Warning limit: below 300 seconds. - Vubiq RF RX FEC Errors, OID: 1.3.6.1.4.1.46330.2.2.1.23.0
The raw FEC correctable error counts. Counter32, Read Only
The entire list of Vubiq V60s SNMP variables can be found here.
To have your terminal’s performance monitored and tracked or for more information about Vubiq’s SNMP Data please contact Michael Klett.